Inverse square law
Also called: radiation distance law, I1/I2 = D2^2/D1^2
Definition
The inverse square law states that the intensity of an X-ray beam is inversely proportional to the square of the distance from the point source. As the beam travels outward from the focal spot, the same number of photons spreads over an area that grows with the square of the distance. Doubling the distance from the source reduces radiation intensity to one-fourth of its original value, while halving the distance quadruples the intensity.
How Inverse square law Is Tested on the Registry Exam
ARRT Safety and Image Production questions use the inverse square law to calculate technologist exposure at different standing distances and receptor intensity changes when SID is modified.
ARRT Radiography Exam Overview (2026)
Inverse square law is part of the core curriculum for the ARRT Radiography Certification (R.T.(R)) exam.
- Questions
- 230 (200 scored)
- Time Limit
- 3 hours 50 minutes
- Passing Score
- 75 (1-99)
- Test Provider
- Pearson VUE
Official Radiography Content Domains
Textbook & Clinical References
- Bushong, S. C. Radiologic Science for Technologists: Physics, Biology, and Protection.
Related Radiography Physics, Image Production and Radiation Safety Terms
View all 22 terms →Anode heel effect
The anode heel effect is the variation in X-ray beam intensity along the cathode-to-anode axis of the tube, caused by target material absorbing some of the photons emitted toward the anode side. As a result, the beam is more intense on the cathode side and up to 25 to 45 percent less intense on the anode side. The effect becomes more pronounced with smaller anode target angles, shorter source-to-image receptor distances (SID), and larger field sizes. Technologists use it clinically by placing the thicker, denser part of the anatomy under the cathode side.
Read definition & exam tips →
Line-focus principle
The line-focus principle is the geometric design of an angled X-ray tube anode target so that the actual focal spot (the area struck by electrons, which dissipates heat) remains large, while the effective focal spot projected downward toward the patient and image receptor is much smaller. Decreasing the anode target angle makes the effective focal spot smaller, improving spatial resolution, while keeping a large actual focal spot to handle high heat loads.
Read definition & exam tips →
Compton scattering
Compton scattering is an interaction in which an incoming X-ray photon strikes a loosely bound outer-shell electron in tissue, ejects that electron (a Compton recoil electron), and continues in a new direction with reduced energy as a scattered photon. Its probability depends primarily on tissue electron density rather than atomic number, and it predominates at higher diagnostic kVp levels. Scattered photons carry no useful anatomical information: those reaching the image receptor degrade contrast through fog, and those leaving the patient are the primary source of occupational radiation exposure to staff.
Read definition & exam tips →
Photoelectric effect
The photoelectric effect is an interaction in which an incident X-ray photon transfers all of its energy to a tightly bound inner-shell (typically K-shell) electron of a tissue atom, completely absorbing the photon and ejecting the electron as a photoelectron. Another electron then drops into the inner-shell vacancy, releasing low-energy characteristic radiation. The likelihood of photoelectric absorption rises sharply with the third power of the absorber's atomic number (Z^3) and falls rapidly as photon energy (kVp) increases, which is why dense bone and barium or iodine contrast agents appear bright white on radiographs.
Read definition & exam tips →
Bremsstrahlung radiation
Bremsstrahlung (German for braking) radiation is produced inside the X-ray tube when a high-speed projectile electron from the cathode passes close to the positively charged nucleus of a tungsten target atom, slows down, and changes direction. The kinetic energy lost by the decelerating electron is emitted directly as an X-ray photon. Because electrons pass at varying distances from target nuclei and lose anywhere from a tiny fraction to all of their kinetic energy, bremsstrahlung produces a continuous spectrum of photon energies up to the selected kVp, accounting for the majority of diagnostic X-ray photons.
Read definition & exam tips →
Characteristic radiation
Characteristic radiation is produced in the X-ray tube target when a projectile electron has enough kinetic energy to eject an inner-shell (K-shell) electron from a target atom, leaving a vacancy that is filled by an outer-shell electron dropping down. The emitted X-ray photon has a discrete energy exactly equal to the difference in binding energies between the two shells. For a tungsten target, K-shell electrons have a binding energy of 69.5 keV, so useful K-characteristic X-rays are produced only when the tube is operated at 70 kVp or higher.