Radiography & X-Ray Physics (ARRT)

Radiography vs. radiology

Also called: radiographer vs radiologist, rad tech vs radiologist

Definition

Radiography is the allied health profession and technical discipline of positioning patients, selecting exposure factors (kVp, mAs, SID, AEC), applying radiation protection (ALARA), and acquiring diagnostic medical images, performed by a registered radiologic technologist (R.T.(R)(ARRT)). Radiology is the medical specialty practiced by a licensed physician (MD or DO) who completes a four-year diagnostic radiology residency to interpret medical images, render formal diagnostic reports, and perform image-guided interventional procedures.

How Radiography vs. radiology Is Tested on the Registry Exam

ARRT Patient Care and professional ethics questions test the legal scope of practice of a radiologic technologist: gathering clinical history, verifying orders, positioning, and evaluating images for technical quality, while never providing a medical diagnosis to the patient.

ARRT Radiography Exam Overview (2026)

Radiography vs. radiology is part of the core curriculum for the ARRT Radiography Certification (R.T.(R)) exam.

Full Radiography Study Guide →
Questions
230 (200 scored)
Time Limit
3 hours 50 minutes
Passing Score
75 (1-99)
Test Provider
Pearson VUE

Official Radiography Content Domains

Patient Care16.5%
Safety25%
Image Production25.5%
Procedures33%

Textbook & Clinical References

  • ASRT Practice Standards for Medical Imaging and Radiation Therapy.

Related Radiography Physics, Image Production and Radiation Safety Terms

View all 22 terms →

MRI safety zones (ACR Zones I to IV)

The American College of Radiology (ACR) defines four progressive MRI safety zones to prevent ferromagnetic projectile accidents, thermal burns, and implanted device malfunction around the always-on superconducting magnet. Zone I is public access outside the MR environment; Zone II is the supervised reception, dressing, and patient screening interface; Zone III is the restricted control room area where unscreened personnel or ferromagnetic objects can cause serious injury and access is strictly controlled by MR personnel; and Zone IV is the physical magnet room itself, which contains the strong static magnetic field (B0) at all times, even when no scan is running.

Read definition & exam tips →

Milliamperage and mAs

Milliamperage (mA) measures the X-ray tube current, which determines the rate at which electrons flow from the cathode filament to the anode target. Multiplying tube current (mA) by exposure time in seconds (s) gives milliampere-seconds (mAs), the primary technical factor controlling the total quantity of X-ray photons produced and the patient radiation dose. Doubling mAs doubles both the number of photons reaching the image receptor and the patient dose, without changing the maximum energy or penetrating power of the beam.

Read definition & exam tips →

Kilovoltage peak (kVp)

Kilovoltage peak (kVp) is the maximum electrical potential difference applied across the X-ray tube between the cathode and anode, measured in thousands of volts. It sets the maximum kinetic energy of the projectile electrons and therefore the maximum energy and penetrating ability (quality) of the resulting X-ray beam. Raising kVp increases both the average photon energy and the percentage of photons that penetrate the patient to reach the image receptor, while also increasing the proportion of Compton scatter.

Read definition & exam tips →

15 percent kVp rule

The 15 percent kVp rule is a practical radiographic exposure relationship stating that increasing kVp by 15 percent has the same effect on image receptor exposure as doubling the mAs, while decreasing kVp by 15 percent has the same effect as cutting the mAs in half. When a technologist wants to maintain equal receptor exposure while reducing patient radiation dose, raising kVp by 15 percent and halving mAs lowers the entrance skin dose because fewer total photons are needed when each photon is more penetrating.

Read definition & exam tips →

Dose-area product (DAP)

Dose-area product (DAP), also called kerma-area product (KAP), is the absorbed radiation dose in air multiplied by the cross-sectional area of the X-ray beam at that point, commonly expressed in milligray-centimeters squared (mGy·cm2) or microgray-meters squared. Unlike air kerma at a single point, DAP accounts for both the intensity of the beam and the field size (collimation). Because scattered radiation shifts proportionally with beam area, tightly collimating the X-ray field directly reduces DAP even if the central-ray exposure factors remain unchanged.

Read definition & exam tips →

Detective quantum efficiency (DQE)

Detective quantum efficiency (DQE) measures how effectively a digital image receptor converts incoming X-ray photons into a useful output image signal without adding extra noise, expressed as a percentage or ratio from 0 to 1. A receptor with a higher DQE can produce the same signal-to-noise ratio (image quality) at a lower patient radiation dose. Cesium iodide (CsI) indirect flat-panel detectors and amorphous selenium direct detectors generally achieve higher DQE values than computed radiography (CR) photostimulable phosphor plates.

Read definition & exam tips →