Milliamperage and mAs
Also called: mA, mAs, milliampere-seconds
Definition
Milliamperage (mA) measures the X-ray tube current, which determines the rate at which electrons flow from the cathode filament to the anode target. Multiplying tube current (mA) by exposure time in seconds (s) gives milliampere-seconds (mAs), the primary technical factor controlling the total quantity of X-ray photons produced and the patient radiation dose. Doubling mAs doubles both the number of photons reaching the image receptor and the patient dose, without changing the maximum energy or penetrating power of the beam.
How Milliamperage and mAs Is Tested on the Registry Exam
ARRT Radiography questions test mAs reciprocity (different mA and time combinations that yield the same total mAs), the direct 1-to-1 proportionality between mAs and receptor exposure or patient dose, and why mAs controls quantum noise rather than beam penetration.
ARRT Radiography Exam Overview (2026)
Milliamperage and mAs is part of the core curriculum for the ARRT Radiography Certification (R.T.(R)) exam.
- Questions
- 230 (200 scored)
- Time Limit
- 3 hours 50 minutes
- Passing Score
- 75 (1-99)
- Test Provider
- Pearson VUE
Official Radiography Content Domains
Video Lessons Covering Milliamperage and mAs
Review these related video lessons from Prepry's registry review courses.
Abdominal Transplants and Postoperative Assessment - Part 2
Evaluate postoperative transplant complications including surgical trauma, hematomas, and seromas. Distinguish between abscesses and lymphoceles using sonographic features like peripheral vascularity and echogenicity to ensure graft longevity. ARDMS, ARRT, and CCI registry exam preparation.
Abdominal Transplants and Postoperative Assessment - Part 1
Explore sonographic evaluation of liver, kidney, and pancreas transplants including preoperative vascular mapping and postoperative monitoring. Master Doppler techniques for assessing hepatic artery patency, resistive index values, and identifying complications like thrombosis. ARDMS, ARRT, and CCI registry exam preparation.
Abdominal Imaging Optimization
Master the principles of ultrasound physics including frequency, wavelength, and attenuation to optimize abdominal imaging. Learn how to select the appropriate curvilinear or linear transducer based on patient habitus and target depth. ARDMS, ARRT, and CCI registry exam preparation.
Imaging Artifacts - Part 2
Explore equipment-related artifacts including electrical interference, transducer malfunction, and vertical dropout. Master the identification of twinkle artifact for renal calculi and understand the physics behind spectral Doppler aliasing and the Nyquist limit. ARDMS, ARRT, and CCI registry exam preparation.
Textbook & Clinical References
- Bushong, S. C. Radiologic Science for Technologists: Physics, Biology, and Protection.
- ARRT Radiography Examination Content Specifications
Related Radiography Physics, Image Production and Radiation Safety Terms
View all 22 terms →Kilovoltage peak (kVp)
Kilovoltage peak (kVp) is the maximum electrical potential difference applied across the X-ray tube between the cathode and anode, measured in thousands of volts. It sets the maximum kinetic energy of the projectile electrons and therefore the maximum energy and penetrating ability (quality) of the resulting X-ray beam. Raising kVp increases both the average photon energy and the percentage of photons that penetrate the patient to reach the image receptor, while also increasing the proportion of Compton scatter.
Read definition & exam tips →
15 percent kVp rule
The 15 percent kVp rule is a practical radiographic exposure relationship stating that increasing kVp by 15 percent has the same effect on image receptor exposure as doubling the mAs, while decreasing kVp by 15 percent has the same effect as cutting the mAs in half. When a technologist wants to maintain equal receptor exposure while reducing patient radiation dose, raising kVp by 15 percent and halving mAs lowers the entrance skin dose because fewer total photons are needed when each photon is more penetrating.
Read definition & exam tips →
Dose-area product (DAP)
Dose-area product (DAP), also called kerma-area product (KAP), is the absorbed radiation dose in air multiplied by the cross-sectional area of the X-ray beam at that point, commonly expressed in milligray-centimeters squared (mGy·cm2) or microgray-meters squared. Unlike air kerma at a single point, DAP accounts for both the intensity of the beam and the field size (collimation). Because scattered radiation shifts proportionally with beam area, tightly collimating the X-ray field directly reduces DAP even if the central-ray exposure factors remain unchanged.
Read definition & exam tips →
Detective quantum efficiency (DQE)
Detective quantum efficiency (DQE) measures how effectively a digital image receptor converts incoming X-ray photons into a useful output image signal without adding extra noise, expressed as a percentage or ratio from 0 to 1. A receptor with a higher DQE can produce the same signal-to-noise ratio (image quality) at a lower patient radiation dose. Cesium iodide (CsI) indirect flat-panel detectors and amorphous selenium direct detectors generally achieve higher DQE values than computed radiography (CR) photostimulable phosphor plates.
Read definition & exam tips →
Inverse square law
The inverse square law states that the intensity of an X-ray beam is inversely proportional to the square of the distance from the point source. As the beam travels outward from the focal spot, the same number of photons spreads over an area that grows with the square of the distance. Doubling the distance from the source reduces radiation intensity to one-fourth of its original value, while halving the distance quadruples the intensity.
Read definition & exam tips →
Anode heel effect
The anode heel effect is the variation in X-ray beam intensity along the cathode-to-anode axis of the tube, caused by target material absorbing some of the photons emitted toward the anode side. As a result, the beam is more intense on the cathode side and up to 25 to 45 percent less intense on the anode side. The effect becomes more pronounced with smaller anode target angles, shorter source-to-image receptor distances (SID), and larger field sizes. Technologists use it clinically by placing the thicker, denser part of the anatomy under the cathode side.
Read definition & exam tips →