Radiography & X-Ray Physics (ARRT)

Sacrum and coccyx X-ray positioning (AP Axial & Lateral projections)

Also called: sacrum and coccyx x ray positioning, sacrum x ray, coccyx x ray, ap axial sacrum, ap axial coccyx

Definition

Radiographic positioning of the sacrum and coccyx requires opposite central ray (CR) angulations on the AP axial projections because of the posterior-convex pelvic curve. For the AP axial sacrum, the central ray is angled 15 degrees cephalad and centered 2 inches (5 cm) superior to the pubic symphysis along the midsagittal plane to project the sacrum free of foreshortening. For the AP axial coccyx, the central ray is angled 10 degrees caudad and centered 2 inches (5 cm) superior to the pubic symphysis so the coccygeal segments are projected superior to the pubic bones. For the lateral sacrum and coccyx projection, the perpendicular central ray is centered 3 to 4 inches (8 to 10 cm) posterior to the anterior superior iliac spine (ASIS), using a lead blocker behind the patient to absorb scatter radiation.

How Sacrum and coccyx X-ray positioning (AP Axial & Lateral projections) Is Tested on the Registry Exam

One of the classic ARRT Procedures traps is reversing the CR angles for the sacrum and coccyx: remember that the AP axial sacrum uses a 15-degree cephalad angle, whereas the AP axial coccyx uses a 10-degree caudad angle, with both entering 2 inches superior to the pubic symphysis (and the urinary bladder should be emptied before the exam).

ARRT Radiography Exam Overview (2026)

Sacrum and coccyx X-ray positioning (AP Axial & Lateral projections) is part of the core curriculum for the ARRT Radiography Certification (R.T.(R)) exam.

Full Radiography Study Guide →
Questions
230 (200 scored)
Time Limit
3 hours 50 minutes
Passing Score
75 (1-99)
Test Provider
Pearson VUE

Official Radiography Content Domains

Patient Care16.5%
Safety25%
Image Production25.5%
Procedures33%

Textbook & Clinical References

  • Lampignano JP, Kendrick LE. Bontrager's Textbook of Radiographic Positioning and Related Anatomy. 10th ed. Elsevier; 2021.

Related Radiography Physics, Image Production and Radiation Safety Terms

View all 31 terms →

Sternum X-ray positioning (15-20 degree RAO & Lateral projections)

Routine radiography of the sternum consists of a 15- to 20-degree right anterior oblique (RAO) projection and a lateral projection. A 15- to 20-degree RAO (rather than an LAO or direct PA) is used to project the sternum slightly to the left of the thoracic vertebrae and superimpose it over the homogeneous shadow of the heart rather than the air-filled right lung. A thin-chested (asthenic) patient requires a slightly larger obliquity (~20 degrees) than a deep-chested (hypersthenic) patient (~15 degrees). Most protocols use an orthostatic (shallow breathing) exposure technique (3- to 4-second exposure time with low mA) on the RAO sternum to blur overlying posterior rib markings, while the lateral sternum is acquired on suspended deep inspiration (with arms drawn posteriorly) to protrude the sternum anteriorly.

Read definition & exam tips →

Scapula X-ray positioning (AP & Lateral Y-view projections)

The routine scapula series includes an AP scapula projection and a lateral scapula (RAO or LAO) projection. For the AP scapula, the affected arm is gently abducted 90 degrees with the elbow flexed and the hand supinated (placed beside the head) to draw the lateral portion of the scapula clear of the thoracic rib cage; the perpendicular central ray enters 2 inches (5 cm) inferior to the coracoid process (mid-scapular area), using a slow breathing technique to blur overlying rib detail. For the lateral scapula, the patient is rotated 45 to 60 degrees into an RAO or LAO until the flat body of the scapula is perpendicular to the image receptor, placing the affected arm across the chest to evaluate the scapular body or hanging at the side to evaluate the acromion and coracoid processes.

Read definition & exam tips →

Humerus X-ray positioning (AP, Rotational Lateral & Transthoracic Lateral)

Routine radiography of the humerus requires two orthogonal views visualizing both the shoulder and elbow joints: an AP projection (arm extended in true anatomic position, hand supinated, epicondyles parallel to the image receptor, demonstrating the greater tubercle in profile laterally) and a rotational lateral projection (arm internally rotated with the hand pronated or elbow flexed 90 degrees, epicondyles perpendicular to the image receptor, demonstrating the lesser tubercle in profile medially). If a proximal humerus fracture is suspected, the technologist must never force rotation of the arm; instead, a neutral AP and a transthoracic lateral (Lawrence method, angling the CR 10 to 15 degrees cephalad if the unaffected arm cannot be fully elevated) or trauma scapular Y lateral is performed.

Read definition & exam tips →

Skull radiographic anatomy, positioning lines (OML/IOML) & routine projections

Radiographic anatomy of the skull divides the 22 cranial and facial bones into the 8 cranial bones (frontal, right and left parietal, right and left temporal, occipital, sphenoid, and ethmoid) and 14 facial bones. Accurate skull positioning relies on two primary reference lines that differ by 7 to 8 degrees: the orbitomeatal line (OML, extending from the outer canthus of the eye to the external acoustic meatus) and the infraorbitomeatal line (IOML, or Reid's base line, extending from the infraorbital margin to the EAM). A routine skull series includes the AP axial (Towne) projection (30 degrees caudad to OML or 37 degrees caudad to IOML, projecting the dorsum sellae within the foramen magnum), the PA axial (Caldwell) projection (15 degrees caudad to OML, projecting the petrous ridges in the lower one-third of the orbits), and the lateral skull (IPL perpendicular to IR, IOML parallel to transverse axis, CR perpendicular 2 inches superior to EAM).

Read definition & exam tips →

Milliamperage and mAs

Milliamperage (mA) measures the X-ray tube current, which determines the rate at which electrons flow from the cathode filament to the anode target. Multiplying tube current (mA) by exposure time in seconds (s) gives milliampere-seconds (mAs), the primary technical factor controlling the total quantity of X-ray photons produced and the patient radiation dose. Doubling mAs doubles both the number of photons reaching the image receptor and the patient dose, without changing the maximum energy or penetrating power of the beam.

Read definition & exam tips →

Kilovoltage peak (kVp)

Kilovoltage peak (kVp) is the maximum electrical potential difference applied across the X-ray tube between the cathode and anode, measured in thousands of volts. It sets the maximum kinetic energy of the projectile electrons and therefore the maximum energy and penetrating ability (quality) of the resulting X-ray beam. Raising kVp increases both the average photon energy and the percentage of photons that penetrate the patient to reach the image receptor, while also increasing the proportion of Compton scatter.

Read definition & exam tips →