Skull radiographic anatomy, positioning lines (OML/IOML) & routine projections
Also called: skull radiographic anatomy, skull x ray positioning, oml vs ioml, caldwell skull view
Definition
Radiographic anatomy of the skull divides the 22 cranial and facial bones into the 8 cranial bones (frontal, right and left parietal, right and left temporal, occipital, sphenoid, and ethmoid) and 14 facial bones. Accurate skull positioning relies on two primary reference lines that differ by 7 to 8 degrees: the orbitomeatal line (OML, extending from the outer canthus of the eye to the external acoustic meatus) and the infraorbitomeatal line (IOML, or Reid's base line, extending from the infraorbital margin to the EAM). A routine skull series includes the AP axial (Towne) projection (30 degrees caudad to OML or 37 degrees caudad to IOML, projecting the dorsum sellae within the foramen magnum), the PA axial (Caldwell) projection (15 degrees caudad to OML, projecting the petrous ridges in the lower one-third of the orbits), and the lateral skull (IPL perpendicular to IR, IOML parallel to transverse axis, CR perpendicular 2 inches superior to EAM).
How Skull radiographic anatomy, positioning lines (OML/IOML) & routine projections Is Tested on the Registry Exam
ARRT Procedures questions test the 7-to-8-degree difference between OML and IOML, petrous ridge location on PA projections (0 degrees PA = petrous ridges fill the orbits; 15 degrees caudad Caldwell = lower third of orbits; 25 to 30 degrees caudad = at or below inferior orbital margin), and dorsum sellae evaluation on the Towne view.
ARRT Radiography Exam Overview (2026)
Skull radiographic anatomy, positioning lines (OML/IOML) & routine projections is part of the core curriculum for the ARRT Radiography Certification (R.T.(R)) exam.
- Questions
- 230 (200 scored)
- Time Limit
- 3 hours 50 minutes
- Passing Score
- 75 (1-99)
- Test Provider
- Pearson VUE
Official Radiography Content Domains
Textbook & Clinical References
- Lampignano JP, Kendrick LE. Bontrager's Textbook of Radiographic Positioning and Related Anatomy. 10th ed. Elsevier; 2021.
Related Radiography Physics, Image Production and Radiation Safety Terms
View all 31 terms →Milliamperage and mAs
Milliamperage (mA) measures the X-ray tube current, which determines the rate at which electrons flow from the cathode filament to the anode target. Multiplying tube current (mA) by exposure time in seconds (s) gives milliampere-seconds (mAs), the primary technical factor controlling the total quantity of X-ray photons produced and the patient radiation dose. Doubling mAs doubles both the number of photons reaching the image receptor and the patient dose, without changing the maximum energy or penetrating power of the beam.
Read definition & exam tips →
Kilovoltage peak (kVp)
Kilovoltage peak (kVp) is the maximum electrical potential difference applied across the X-ray tube between the cathode and anode, measured in thousands of volts. It sets the maximum kinetic energy of the projectile electrons and therefore the maximum energy and penetrating ability (quality) of the resulting X-ray beam. Raising kVp increases both the average photon energy and the percentage of photons that penetrate the patient to reach the image receptor, while also increasing the proportion of Compton scatter.
Read definition & exam tips →
15 percent kVp rule
The 15 percent kVp rule is a practical radiographic exposure relationship stating that increasing kVp by 15 percent has the same effect on image receptor exposure as doubling the mAs, while decreasing kVp by 15 percent has the same effect as cutting the mAs in half. When a technologist wants to maintain equal receptor exposure while reducing patient radiation dose, raising kVp by 15 percent and halving mAs lowers the entrance skin dose because fewer total photons are needed when each photon is more penetrating.
Read definition & exam tips →
Dose-area product (DAP)
Dose-area product (DAP), also called kerma-area product (KAP), is the absorbed radiation dose in air multiplied by the cross-sectional area of the X-ray beam at that point, commonly expressed in milligray-centimeters squared (mGy·cm2) or microgray-meters squared. Unlike air kerma at a single point, DAP accounts for both the intensity of the beam and the field size (collimation). Because scattered radiation shifts proportionally with beam area, tightly collimating the X-ray field directly reduces DAP even if the central-ray exposure factors remain unchanged.
Read definition & exam tips →
Detective quantum efficiency (DQE)
Detective quantum efficiency (DQE) measures how effectively a digital image receptor converts incoming X-ray photons into a useful output image signal without adding extra noise, expressed as a percentage or ratio from 0 to 1. A receptor with a higher DQE can produce the same signal-to-noise ratio (image quality) at a lower patient radiation dose. Cesium iodide (CsI) indirect flat-panel detectors and amorphous selenium direct detectors generally achieve higher DQE values than computed radiography (CR) photostimulable phosphor plates.
Read definition & exam tips →
Inverse square law
The inverse square law states that the intensity of an X-ray beam is inversely proportional to the square of the distance from the point source. As the beam travels outward from the focal spot, the same number of photons spreads over an area that grows with the square of the distance. Doubling the distance from the source reduces radiation intensity to one-fourth of its original value, while halving the distance quadruples the intensity.
Read definition & exam tips →