Radiography & X-Ray Physics (ARRT)

ALARA and cardinal principles of radiation protection

Also called: ALARA, time distance shielding

Definition

ALARA (As Low As Reasonably Achievable) is the foundational regulatory principle of radiation safety, requiring that every radiation exposure be kept as low as practical while still achieving diagnostic image quality. For occupational protection during fluoroscopy and mobile radiography, ALARA is implemented through three cardinal principles: minimizing exposure time, maximizing distance from the radiation source (the patient in scatter exposure), and using protective lead shielding (typically 0.5 mm lead-equivalent aprons and thyroid collars).

How ALARA and cardinal principles of radiation protection Is Tested on the Registry Exam

ARRT Safety questions test where a technologist should stand during C-arm fluoroscopy (on the image receptor/intensifier side, away from the X-ray tube side where patient entrance scatter is highest) and how time, distance, and shielding reduce occupational dose.

ARRT Radiography Exam Overview (2026)

ALARA and cardinal principles of radiation protection is part of the core curriculum for the ARRT Radiography Certification (R.T.(R)) exam.

Full Radiography Study Guide →
Questions
230 (200 scored)
Time Limit
3 hours 50 minutes
Passing Score
75 (1-99)
Test Provider
Pearson VUE

Official Radiography Content Domains

Patient Care16.5%
Safety25%
Image Production25.5%
Procedures33%

Video Lessons Covering ALARA and cardinal principles of radiation protection

Review these related video lessons from Prepry's registry review courses.

Textbook & Clinical References

  • NCRP Report No. 116: Limitation of Exposure to Ionizing Radiation.

Related Radiography Physics, Image Production and Radiation Safety Terms

View all 22 terms →

Effective dose and annual occupational dose limits

Effective dose, measured in sieverts (Sv) or millisieverts (mSv), estimates the whole-body stochastic risk of ionizing radiation by multiplying the absorbed dose (in gray) by both the radiation weighting factor (1 for X-rays) and the tissue weighting factor for each irradiated organ's radiosensitivity. Under NCRP Report No. 116 guidelines tested on the ARRT exam, the annual occupational effective dose limit for a radiation worker is 50 mSv (5 rem) per year, the cumulative lifetime limit is 10 mSv multiplied by age in years, and the limit for a declared pregnant worker's embryo or fetus is 5 mSv (0.5 rem) for the entire gestation (0.5 mSv per month).

Read definition & exam tips →

Radiography vs. radiology

Radiography is the allied health profession and technical discipline of positioning patients, selecting exposure factors (kVp, mAs, SID, AEC), applying radiation protection (ALARA), and acquiring diagnostic medical images, performed by a registered radiologic technologist (R.T.(R)(ARRT)). Radiology is the medical specialty practiced by a licensed physician (MD or DO) who completes a four-year diagnostic radiology residency to interpret medical images, render formal diagnostic reports, and perform image-guided interventional procedures.

Read definition & exam tips →

MRI safety zones (ACR Zones I to IV)

The American College of Radiology (ACR) defines four progressive MRI safety zones to prevent ferromagnetic projectile accidents, thermal burns, and implanted device malfunction around the always-on superconducting magnet. Zone I is public access outside the MR environment; Zone II is the supervised reception, dressing, and patient screening interface; Zone III is the restricted control room area where unscreened personnel or ferromagnetic objects can cause serious injury and access is strictly controlled by MR personnel; and Zone IV is the physical magnet room itself, which contains the strong static magnetic field (B0) at all times, even when no scan is running.

Read definition & exam tips →

Milliamperage and mAs

Milliamperage (mA) measures the X-ray tube current, which determines the rate at which electrons flow from the cathode filament to the anode target. Multiplying tube current (mA) by exposure time in seconds (s) gives milliampere-seconds (mAs), the primary technical factor controlling the total quantity of X-ray photons produced and the patient radiation dose. Doubling mAs doubles both the number of photons reaching the image receptor and the patient dose, without changing the maximum energy or penetrating power of the beam.

Read definition & exam tips →

Kilovoltage peak (kVp)

Kilovoltage peak (kVp) is the maximum electrical potential difference applied across the X-ray tube between the cathode and anode, measured in thousands of volts. It sets the maximum kinetic energy of the projectile electrons and therefore the maximum energy and penetrating ability (quality) of the resulting X-ray beam. Raising kVp increases both the average photon energy and the percentage of photons that penetrate the patient to reach the image receptor, while also increasing the proportion of Compton scatter.

Read definition & exam tips →

15 percent kVp rule

The 15 percent kVp rule is a practical radiographic exposure relationship stating that increasing kVp by 15 percent has the same effect on image receptor exposure as doubling the mAs, while decreasing kVp by 15 percent has the same effect as cutting the mAs in half. When a technologist wants to maintain equal receptor exposure while reducing patient radiation dose, raising kVp by 15 percent and halving mAs lowers the entrance skin dose because fewer total photons are needed when each photon is more penetrating.

Read definition & exam tips →